A heat pump in Bothell, WA works in both seasons, so its repair or replacement starts with how it behaves in each. Bothell has, on average, 25 days a year with a low of 32°F or colder and about one at 20°F or colder (NOAA 1991–2020 normals, station 6 miles away). Half the homes in Bothell were built in 1992 or later (Census ACS 2019–2023). A split heat pump made since January 1, 2023 must rate at least 14.3 SEER2 and 7.5 HSPF2, a federal floor that does not change from state to state.

(888) 217-3739

Washington contractors. No obligation for the call.

The year in Bothell—cooling runs nearly all year
The year in Bothell. cooling runs nearly all year. There is no month when both systems are idle. JFMAMJJASOND
heatingcooling25 days below freezing · July dew point 54°F
A technician checking the coil of an outdoor heat pump in winter
The top grille off, frost across the coil. A heat pump melts that off on a schedule of its own, which looks like a fault and is not.

A heat pump blowing air that feels cool in winter is usually working as designed, and a heat pump that sits on auxiliary heat for hours in mild weather usually is not. Say what the thermostat reads and a heating and cooling contractor can come out to Bothell and tell the two apart.

Sizing here runs the opposite way from a cold climate: the cooling load sets the size, exactly as it would for an air conditioner, because it is the load that exists for most of the year — which is correct, and it also means that on the handful of genuinely cold mornings the machine runs without stopping and the strips carry what it cannot. Continuous running on a cold morning is the machine doing its job, not failing at it.

The backup gets sized for the winter this place actually has, which is the sensible way round and has one consequence worth knowing: a strip bank put in for a mild January holds less in reserve than the one the same house would get further north. A cold snap that another state would call ordinary finds that limit, and the house falls behind while the outdoor unit runs and tests fine. What has to be answered then is not what broke, but whether anything did, and that is a measurement rather than a guess.

Summer air here carries less water than it does further east, and air holding less water cools off faster once the sun is down. That puts a wide gap between afternoon and dawn, and in spring and autumn a heat pump answers both ends of it in a single day — cooling in the afternoon, heating before sunrise, with nobody switching anything over. The cost of that is hidden in the thermostat: set the heating and cooling numbers close together and the system changes direction several times a day, and every change is the reversing valve moving and the compressor starting again. Ask where the changeover band sits — it is a setting, not a repair.

Bothell, WA in numbers

Days a year with a low of 32°F or colder25NOAA 1991–2020 normals, station 6 miles away
Days a year with a low of 20°F or colder1NOAA 1991–2020 normals
Average July dew point54°FPRISM 1991–2020 normals
Median year homes were built1992Census ACS 2019–2023
Households18,735Census ACS 2019–2023
CountyKing CountyCensus Bureau
Federal minimum for a new split central AC13.4 SEER2 (North region)DOE, 2023 standard

Why heat pumps in Bothell do not fix themselves

The parts that cycle fail first, and they rarely fail alone. A run capacitor that has lost capacitance does not stop the compressor — it raises the current the compressor draws every minute it runs, and the heat that comes with it. A heat pump asks for that on the heating side as well as the cooling one, where an AC only ever runs to cool, so the part that fails at the end of it is not the capacitor. A capacitor is a part; a compressor is a large fraction of the machine, and on a system installed before 2010 that is where the conversation turns to replacement.

A technician at an indoor air handler

When to stop and call in Bothell

  • The thermostat sits on auxiliary or emergency heat for hours while it is mild outside.
  • The breaker feeding the outdoor unit or the air handler will not stay in.
  • Refrigerant was added in an earlier season and the system is behaving the same way again.
The license
Held by the contractor, not by this site, and issued where the work happens — Washington licenses at state level, at city level or not at all depending on the trade and the town. Ask for the number and the name it is held under: a trading name and the licensed entity are often not the same.
The figure
Set by the contractor and said before the work starts. This site never quotes and has no part in it. If a technician cannot say what the visit covers before beginning, that is the moment to stop.
The call
Describing what the system is doing commits you to nothing. Nothing is booked until you say so.

What happens on the visit

  1. 01

    The diagnosis

    At the thermostat first, then at the furnace or the condenser, in the order the equipment runs. What the system is doing is established before any part is named.

  2. 02

    The finding, out loud

    What failed, whether it is the fault or a symptom of another one, and whether the repair suits the age of the system. A diagnostic visit is usually charged separately from the repair — ask whether it is credited if the work goes ahead, because that differs from one contractor to the next.

  3. 03

    The repair

    Agreed with the contractor before it starts. Where a part has to be ordered, a technician says so rather than leaving the system apart.

Before you call: what to have ready

  1. 01That it is a heat pump, and what the backup is — electric, or a gas furnace on the same ducts, and not knowing is a fair answer.
  2. 02What the thermostat is set to, what it is reading, and whether it shows auxiliary or emergency heat.
  3. 03What the outdoor unit is doing: iced over, silent, running without stopping, or reversing every few minutes.

Emergency heat is what that setting is for if the house has gone cold, but say on the phone that you switched to it, because it locks out the compressor, and the fault a technician needs to watch stops happening while it is on.

Heat Pumps in Bothell: questions

How cold does Bothell get in winter?

Bothell averages 25 days a year with a low of 32°F or colder and 1 at 20°F or colder, by the 1991–2020 climate normals for a NOAA station 6 miles away. Heating is a handful of mornings here, so a heat pump spends nearly the whole year cooling.

What is the July dew point in Bothell?

The July dew point in Bothell averages 54°F, by the PRISM 1991–2020 climate normals. In air that dry most of the cooling load is heat, and an air conditioner removes little water, so sizing turns on the house and its sun more than on humidity.

Is a new R-410A system still allowed in Bothell?

Federally, yes, for equipment made or imported before January 1, 2025: the EPA dropped the January 1, 2026 installation deadline for that stock in a rule effective July 27, 2026. What has been made since January 1, 2025 runs on R-454B or R-32, and those outdoor units are not a listed match for a coil built for R-410A.