Furnace and heating repair in Union, LA starts at the thermostat and follows the equipment through its start-up sequence to the step where it stops. Union averages 16 days a year with a low of 32°F or colder and almost none at 20°F or colder (NOAA 1991–2020 normals, station 8 miles away). Half the homes in Union were built before 1977 (Census ACS 2019–2023). When the gas utility finds a leak or an unsafe furnace it shuts the gas off and tags the appliance, and only a repair brings the gas back.

(888) 217-3739

Louisiana contractors. No obligation for the call.

The year in Union—cooling runs nearly all year
The year in Union. cooling runs nearly all year. There is no month when both systems are idle. JFMAMJJASOND
heatingcooling16 days below freezing · July dew point 74°F
A technician with a meter at the open panel of a gas furnace
A meter at the burner assembly with the panel off. The ignition sequence runs in a fixed order, and the step where it stops is what names the part.

No heat on a cold night comes down to a short list of faults, and the step where the sequence stops names the part. Say what heats the house, what the thermostat is asking for against what it says the room is, and what the equipment is actually doing, and a heating contractor who covers Union takes it from there.

Where the heat comes from a heat pump, no heat usually means it stopped heating rather than stopped running. The reversing valve is what decides which job the machine is doing, and one that sticks leaves an outdoor unit sounding normal and air at the registers that never warms. Where the heating comes from a small gas furnace instead, the list is the familiar one: flame sensor, ignitor, pressure switch, limit switch.

Air from the vents that feels cool in winter is not a fault by itself — a heat pump works on a smaller difference between the room and the air it supplies, and it runs longer cycles to make that up. What matters is whether the room gets to the number on the thermostat, and whether the electric strips are doing work the heat pump should be doing: a thermostat set or wired wrong brings them on when the weather never asked for them.

Where July dew points sit at 70°F and above, the indoor coil runs wet all summer, and everything it pulls out of the air leaves by one drain line. A summer of that grows a film inside the trap and the line, and nobody thinks about a drain on the first cold night: a condensing furnace makes water of its own, in most installations it goes down that same line, and a line that will not take it backs the water up until the pressure switch refuses to close. So a no-heat call in a climate like this can end at the drain rather than at the burner.

Union, LA in numbers

Days a year with a low of 32°F or colder16NOAA 1991–2020 normals, station 8 miles away
Days a year with a low of 20°F or colderfewer than oneNOAA 1991–2020 normals
Average July dew point74°FPRISM 1991–2020 normals
Median year homes were built1977Census ACS 2019–2023
Households149Census ACS 2019–2023
CountySt. James ParishCensus Bureau
Federal minimum for a new split central AC14.3 SEER2 under 45,000 Btu/h (Southeast)DOE, 2023 standard

Why heating faults in Union do not fix themselves

A furnace that only runs after a reset is not a furnace that is working. Each lockout is a control board refusing to try again after a safety did not prove — the flame, the pressure switch or the limit — and a reset settles none of it. What a reset does change is the wear: a furnace short cycling through a cold week runs its ignition sequence dozens of times a day, and the ignitor and the inducer motor are the parts paying for it.

A heating tune-up before the season

What a technician checks on a heating maintenance visit is concrete, and worth naming on the phone: the ignition sequence run from start to finish, the flame sensor cleaned and its signal read, the temperature rise measured across the furnace, the heat exchanger looked over for cracks, carbon monoxide checked at the flue, and the drain cleared. On a heat pump the list adds the defrost cycle and the auxiliary heat strips; on a boiler, the pressure, the relief valve and the circulator.

A technician at an indoor air handler

When to stop and call in Union

  • There is a tag on the furnace and the gas supply has been shut off.
  • The blower runs and the air never warms, or the thermostat is asking for heat while the reading keeps dropping.
  • Water is standing at the base of the furnace, or the flue outside has iced over.
The license
Held by the contractor, not by this site, and issued where the work happens — Louisiana licenses at state level, at city level or not at all depending on the trade and the town. Ask for the number and the name it is held under: a trading name and the licensed entity are often not the same.
The call
Describing what the system is doing commits you to nothing. Nothing is booked until you say so.
Coverage
By town, not by region. Union and the towns around it, and it shifts with who is taking calls at the hour you ring.

What happens on the visit

  1. 01

    The diagnosis

    At the thermostat first, then at the furnace or the condenser, in the order the equipment runs. What the system is doing is established before any part is named.

  2. 02

    The repair

    Agreed with the contractor before it starts. Where a part has to be ordered, a technician says so rather than leaving the system apart.

  3. 03

    What happens after

    A system that failed once in a season often fails again in it. Whether that is the same fault or a second one is worth asking while the technician is still there.

What to have ready when you call from Union

  1. 01Which system it is: a furnace, a boiler with radiators or baseboard, or a heat pump with electric backup.
  2. 02What it is doing: silent, clicking and stopping, lighting and dropping out, or running with cold air at the vents.
  3. 03Whether the gas utility has already been to the house, and whether there is a tag on the appliance.

Do not keep pressing the reset while you wait — each press relights a furnace that shut itself down for a reason, and the lockout it is holding is the first thing a technician reads.

Heating Repair in Union: questions

How many freezing days does Union have?

Union averages 16 days a year with a low of 32°F or colder and almost none at 20°F or colder, by the 1991–2020 climate normals for a NOAA station 8 miles away. Heating is rarely asked for here, so a fault in it can sit unnoticed until the one cold week of the year.

How old are the homes in Union?

Half the homes in Union were built before 1977, by the Census Bureau's 2019–2023 American Community Survey. Detached houses make up about half of the housing. Equipment in houses of that age is often on its second set, and the install date on the label decides whether parts are still made. Manufactured homes are common enough here that a packaged unit outside, feeding a duct under the floor, is worth mentioning on the call.

How efficient must a new gas furnace be?

The federal minimum for a new non-weatherized gas furnace is an AFUE of 80. A 95 standard is set for furnaces made after December 18, 2028 and is still in court, so a furnace going in now can be an 80 or a condensing model in the 90s.

Map loads when you reach it

Other services in Union

Heating Repair nearby