Heat pump repair in Schertz, TX starts by telling a normal defrost cycle or auxiliary-heat run from one that is a fault. Schertz averages 12 days a year with a low of 32°F or colder and almost none at 20°F or colder (NOAA 1991–2020 normals, station in or next to town). Half the homes in Schertz were built in 2001 or later (Census ACS 2019–2023). A split heat pump made since January 1, 2023 must rate at least 14.3 SEER2 and 7.5 HSPF2, a federal floor that does not change from state to state.
(888) 217-3739Texas contractors. No obligation for the call.
A heat pump blowing air that feels cool in winter is usually working as designed, and a heat pump that sits on auxiliary heat for hours in mild weather usually is not. Say what the thermostat reads and a heating and cooling contractor can come out to Schertz and tell the two apart.
In Schertz the cooling season is the year and the heating season is a handful of mornings. What a no-heat call means here depends on what else the house has: where there is a furnace, the heat pump has something to hand the load to, and where there is none — and in this climate plenty of houses have none — the only thing behind it is a bank of electric resistance strips. That is the first thing a technician establishes, because there is no second appliance to switch to.
That makes the sizing question run the opposite way from a cold climate: the cooling load sets the size, exactly as it would for an air conditioner, because it is the load that exists for most of the year — which is correct, and it also means that on the handful of genuinely cold mornings the machine runs without stopping and the strips carry what it cannot. Continuous running on a cold morning is the machine doing its job, not failing at it.
Sizing a heat pump means sizing for two jobs at once, and in a July this wet they pull against each other. Sized for the coldest night, it is oversized for the cooling season: it drops the temperature, shuts off, and never runs long enough to pull water out of the air, so the thermostat reads 74°F and the house still feels damp. That is where a single-stage machine runs out of options, and it is the argument for a compressor that modulates rather than one that is simply larger — long, slow run cycles are what dehumidify. Ask what the sizing was based on: a measurement of the house, with the heating load and the cooling load worked out separately.
Schertz, TX in numbers
| Days a year with a low of 32°F or colder | 12 | NOAA 1991–2020 normals, station in or next to town |
|---|---|---|
| Days a year with a low of 20°F or colder | fewer than one | NOAA 1991–2020 normals |
| Average July dew point | 70°F | PRISM 1991–2020 normals |
| Median year homes were built | 2001 | Census ACS 2019–2023 |
| Households | 15,571 | Census ACS 2019–2023 |
| County | Comal County | Census Bureau |
| Federal minimum for a new split central AC | 14.3 SEER2 under 45,000 Btu/h (Southeast) | DOE, 2023 standard |
Before you try the store-bought fix
The small can with a gauge on top is sold for car air conditioners, and that is not an accident: a homeowner cannot buy R-410A or R-454B over the counter. The EPA restricts the sale of those refrigerants to certified technicians, and refrigerant for a car air conditioner is the exception that keeps the can on the shelf. Even where a fitting could be made to work, a technician sets the charge by measurement rather than by a gauge reading — superheat and subcooling, read at the machine, and read differently in heating mode than in cooling. And a working system does not consume refrigerant: a heat pump that needs more of it has a leak, so the work is finding the leak rather than replacing what escaped.
When to stop and call in Schertz
- It cools in summer but will not heat, or it heats but will not cool.
- The breaker feeding the outdoor unit or the air handler will not stay in.
- Refrigerant was added in an earlier season and the system is behaving the same way again.
- The figure
- Set by the contractor and said before the work starts. This site never quotes and has no part in it. If a technician cannot say what the visit covers before beginning, that is the moment to stop.
- The call
- Describing what the system is doing commits you to nothing. Nothing is booked until you say so.
- Coverage
- By town, not by region. Schertz and the towns around it, and it shifts with who is taking calls at the hour you ring.
What the visit involves
- 01
The diagnosis
At the thermostat first, then at the furnace or the condenser, in the order the equipment runs. What the system is doing is established before any part is named.
- 02
The finding, out loud
What failed, whether it is the fault or a symptom of another one, and whether the repair suits the age of the system. A diagnostic visit is usually charged separately from the repair — ask whether it is credited if the work goes ahead, because that differs from one contractor to the next.
- 03
What happens after
A system that failed once in a season often fails again in it. Whether that is the same fault or a second one is worth asking while the technician is still there.
What to have ready when you call
- 01That it is a heat pump, and what the backup is — electric, or a gas furnace on the same ducts, and not knowing is a fair answer.
- 02What the thermostat is set to, what it is reading, and whether it shows auxiliary or emergency heat.
- 03What the unit outside is doing: iced over, silent, running without stopping, or reversing every few minutes.
If the house has gone cold, emergency heat is what that setting is for — say on the phone that you switched to it, because it locks out the compressor, and the fault a technician needs to watch stops happening while it is on.
Heat Pumps in Schertz: questions
How cold does Schertz get in winter?
Schertz averages 12 days a year with a low of 32°F or colder and almost none at 20°F or colder, by the 1991–2020 climate normals for the NOAA station in or next to town. Heating is a handful of mornings here, so a heat pump spends nearly the whole year cooling.
What is the July dew point in Schertz?
The July dew point in Schertz averages 70°F, by the PRISM 1991–2020 climate normals. In air that wet an oversized air conditioner cools the house fast, shuts off before it has dried the air, and leaves rooms cool and clammy, which is why sizing starts with a load calculation for the house.
Is a new R-410A system still allowed in Schertz?
Federally, yes, for equipment made or imported before January 1, 2025: the EPA dropped the January 1, 2026 installation deadline for that stock in a rule effective July 27, 2026. Equipment made since January 1, 2025 is charged with R-454B or R-32 instead, and an outdoor unit built for those is not a listed match for an indoor coil built for R-410A.