Heat Pump Repair and Replacement in Murphy, TX

A heat pump in Murphy, TX works in both seasons, so its repair or replacement starts with how it behaves in each. Murphy averages 44 days a year with a low of 32°F or colder and 5 at 20°F or colder (NOAA 1991–2020 normals, station 7 miles away). Half the homes in Murphy were built in 2005 or later (Census ACS 2019–2023), so many houses here still run the equipment they were built with. A split heat pump made since January 1, 2023 must rate at least 14.3 SEER2 and 7.5 HSPF2, a federal floor that does not change from state to state.

(888) 217-3739

Texas contractors. No obligation for the call.

The year in Murphy—cooling leads, heating gets weeks
The year in Murphy. cooling leads, heating gets weeks. Between the two seasons there are weeks when neither system runs, which is when a fault goes unnoticed. nothing runsJFMAMJJASOND
heatingcooling44 days below freezing · July dew point 69°F
A technician checking the coil of an outdoor heat pump in winter
The top grille off, frost across the coil. A heat pump melts that off on a schedule of its own, which looks like a fault and is not.

A heat pump blowing air that feels cool in winter is usually working as designed, and a heat pump that sits on auxiliary heat for hours in mild weather usually is not. Say what the thermostat reads and a heating and cooling contractor can come out to Murphy and tell the two apart.

In Murphy a heat pump spends most of its life as an air conditioner, and the heating side runs for a few weeks rather than a season. That shapes which faults get noticed, and when: anything wrong with cooling shows up in July with the whole house paying attention, while anything wrong with heating waits for the first cold week of the year to announce itself.

The part that pattern is hardest on is the reversing valve. It holds one position for most of the year and is then asked to move, and a valve that has sat that long sometimes does not move at all, or stops halfway. A machine that cooled all summer and then blows room-temperature air in the first cold week of December is describing that valve, or the solenoid on it, far more often than a dead compressor.

Frost on the outdoor coil comes out of the air rather than off the ground, which is why the heaviest of it here arrives in weather nobody would call severe. A coil below freezing collects moisture from damp air faster than from cold dry air, so a drizzly morning near 35°F puts more ice on it than a clear night at 15°F does — and a defrost cycle on a mild wet morning is the machine keeping up rather than falling behind. Ice that is still sitting there at the end of the day is the fault version, and it does not clear itself.

Murphy, TX in numbers

Days a year with a low of 32°F or colder44NOAA 1991–2020 normals, station 7 miles away
Days a year with a low of 20°F or colder5NOAA 1991–2020 normals
Average July dew point69°FPRISM 1991–2020 normals
Median year homes were built2005Census ACS 2019–2023
Households5,907Census ACS 2019–2023
CountyCollin CountyCensus Bureau
Federal minimum for a new split central AC14.3 SEER2 under 45,000 Btu/h (Southeast)DOE, 2023 standard

Before you try the store-bought fix

A hard-start kit does what it says on the box, and that is the problem with it. It adds starting torque, and it will carry a compressor that has started to struggle through another season — it is a real part, fitted deliberately on some systems, and not a gimmick. What it does not do is explain why the compressor needed help: a weak run capacitor, worn windings, or a system running at pressures it should not be. A kit fitted and then forgotten hides that question until the compressor answers it.

A technician at an indoor air handler

When to stop and call in Murphy

  • The thermostat sits on auxiliary or emergency heat for hours while it is mild outside.
  • The breaker feeding the outdoor unit or the air handler will not stay in.
  • Refrigerant was added in an earlier season and the system is behaving the same way again.
The figure
Set by the contractor and said before the work starts. This site never quotes and has no part in it. If a technician cannot say what the visit covers before beginning, that is the moment to stop.
The call
Describing what the system is doing commits you to nothing. Nothing is booked until you say so.
Coverage
By town, not by region. Murphy and the towns around it, and it shifts with who is taking calls at the hour you ring.

What happens on the visit

  1. 01

    The diagnosis

    At the thermostat first, then at the furnace or the condenser, in the order the equipment runs. What the system is doing is established before any part is named.

  2. 02

    The finding, out loud

    What failed, whether it is the fault or a symptom of another one, and whether the repair suits the age of the system. A diagnostic visit is usually charged separately from the repair — ask whether it is credited if the work goes ahead, because that differs from one contractor to the next.

  3. 03

    What happens after

    A system that failed once in a season often fails again in it. Whether that is the same fault or a second one is worth asking while the technician is still there.

Before you call: what to have ready

  1. 01That the system is a heat pump, and what carries the heat when it cannot — electric, or a gas furnace on the same ducts, and not knowing is a fair answer.
  2. 02Both thermostat numbers, and whether the display is showing auxiliary or emergency heat.
  3. 03What the unit outside is doing: iced over, silent, running without stopping, or reversing every few minutes.

Emergency heat is what that setting is for if the house has gone cold, but say on the phone that you switched to it, because it locks out the compressor, and the fault a technician needs to watch stops happening while it is on.

Heat Pumps in Murphy: questions

How many freezing days does Murphy have?

Murphy averages 44 days a year with a low of 32°F or colder and 5 at 20°F or colder, by the 1991–2020 climate normals for a NOAA station 7 miles away. Cooling sizes the equipment here, and the few cold mornings are when the backup heat comes on.

What is the July dew point in Murphy?

The July dew point in Murphy averages 69°F, by the PRISM 1991–2020 climate normals. In air that wet an oversized air conditioner cools the house fast, shuts off before it has dried the air, and leaves rooms cool and clammy, which is why sizing starts with a load calculation for the house.

Is a new R-410A system still allowed in Murphy?

Under federal rules, yes, if the equipment was made or imported before January 1, 2025: an EPA rule that took effect on July 27, 2026 removed the January 1, 2026 installation deadline for that stock. What has been made since January 1, 2025 runs on R-454B or R-32, and those outdoor units are not a listed match for a coil built for R-410A.