Heat Pump Repair and Replacement in Markham, TX

Heat pump repair in Markham, TX starts by telling a normal defrost cycle or auxiliary-heat run from one that is a fault. Markham has, on average, 7 days a year with a low of 32°F or colder and almost none at 20°F or colder (NOAA 1991–2020 normals, station 6 miles away). Half the homes in Markham were built before 1971 (Census ACS 2019–2023). A split heat pump made since January 1, 2023 must rate at least 14.3 SEER2 and 7.5 HSPF2, a federal floor that does not change from state to state.

(888) 217-3739

Texas contractors. No obligation for the call.

The year in Markham—cooling runs nearly all year
The year in Markham. cooling runs nearly all year. There is no month when both systems are idle. JFMAMJJASOND
heatingcooling7 days below freezing · July dew point 74°F
A technician checking the coil of an outdoor heat pump in winter
The top grille off, frost across the coil. A heat pump melts that off on a schedule of its own, which looks like a fault and is not.

A heat pump blowing air that feels cool in winter is usually working as designed, and a heat pump that sits on auxiliary heat for hours in mild weather usually is not. Say what the thermostat is showing and a heating and cooling contractor can come out to Markham and tell the two apart.

A heat pump in Markham spends the year on the cooling side, and the heating side is a handful of mornings. What a no-heat call means here depends on what else the house has: where there is a furnace, the heat pump has something to hand the load to, and where there is none — and in this climate plenty of houses have none — the only thing behind it is a bank of electric resistance strips. That is the first thing a technician asks about, because there is no second appliance to switch to.

The backup gets sized for the winter this place actually has, which is the sensible way round and has one consequence worth knowing: a strip bank put in for a mild January holds less in reserve than the one the same house would get further north. A cold snap that another state would call ordinary finds that limit, and the house falls behind while the outdoor unit runs and tests fine. What has to be answered then is not what broke, but whether anything did, and that is a measurement rather than a guess.

A heat pump has to be sized for two different jobs, and in a July this wet the two pull in opposite directions. Sized for the coldest night, it is oversized for the cooling season: it drops the temperature, shuts off, and never runs long enough to pull water out of the air, so the thermostat reads 74°F and the house still feels damp. This is the point where a single-stage machine runs out of options, and it is the argument for a compressor that modulates rather than one that is simply larger — long, slow run cycles are what dehumidify. Ask what the sizing was based on: a measurement of the house, with the heating load and the cooling load worked out separately.

Markham, TX in numbers

Days a year with a low of 32°F or colder7NOAA 1991–2020 normals, station 6 miles away
Days a year with a low of 20°F or colderfewer than oneNOAA 1991–2020 normals
Average July dew point74°FPRISM 1991–2020 normals
Median year homes were built1971Census ACS 2019–2023
Households327Census ACS 2019–2023
CountyMatagorda CountyCensus Bureau
Federal minimum for a new split central AC14.3 SEER2 under 45,000 Btu/h (Southeast)DOE, 2023 standard

Heat pumps do not fix themselves

The parts that cycle fail first, and they rarely fail alone. A run capacitor that has lost capacitance does not shut the compressor down — it raises the current the compressor draws every minute it runs, and the heat that comes with it. A heat pump asks for that on the heating side as well as the cooling one, where an AC only ever runs to cool, so the part that fails at the end of it is not the capacitor. A capacitor is a part; a compressor is a large fraction of the machine, and on a system installed before 2010 that is where the conversation turns to replacement.

A technician at an indoor air handler

When to stop and call

  • It cools in summer but will not heat, or it heats but will not cool.
  • The breaker feeding the outdoor unit or the air handler will not stay in.
  • Refrigerant was added in an earlier season and the system is behaving the same way again.
The license
Held by the contractor, not by this site, and issued where the work happens — Texas licenses at state level, at city level or not at all depending on the trade and the town. Ask for the number and the name it is held under: a trading name and the licensed entity are often not the same.
The figure
Set by the contractor and said before the work starts. This site never quotes and has no part in it. If a technician cannot say what the visit covers before beginning, that is the moment to stop.
The call
Describing what the system is doing commits you to nothing. Nothing is booked until you say so.

What the visit involves

  1. 01

    The diagnosis

    At the thermostat first, then at the furnace or the condenser, in the order the equipment runs. What the system is doing is established before any part is named.

  2. 02

    The repair

    Agreed with the contractor before it starts. Where a part has to be ordered, a technician says so rather than leaving the system apart.

  3. 03

    What happens after

    A system that failed once in a season often fails again in it. Whether that is the same fault or a second one is worth asking while the technician is still there.

Before you call: what to have ready

  1. 01That the system is a heat pump, and what carries the heat when it cannot — electric, or a gas furnace on the same ducts, and not knowing is a fair answer.
  2. 02What the thermostat is set to, what it is reading, and whether it shows auxiliary or emergency heat.
  3. 03What the outdoor unit is doing: iced over, silent, running without stopping, or reversing every few minutes.

Emergency heat is what that setting is for if the house has gone cold, but say on the phone that you switched to it, because it locks out the compressor, and the fault a technician needs to watch stops happening while it is on.

Heat Pumps in Markham: questions

How many freezing days does Markham have?

Markham averages 7 days a year with a low of 32°F or colder and almost none at 20°F or colder, by the 1991–2020 climate normals for a NOAA station 6 miles away. Heating is a handful of mornings here, so a heat pump spends nearly the whole year cooling.

How humid are summers in Markham?

The July dew point in Markham averages 74°F, by the PRISM 1991–2020 climate normals. In air that wet an oversized air conditioner cools the house fast, shuts off before it has dried the air, and leaves rooms cool and clammy, which is why sizing starts with a load calculation for the house.

What efficiency does a new heat pump need in Markham?

The federal minimum for a split heat pump made since January 1, 2023 is 14.3 SEER2 for cooling and 7.5 HSPF2 for heating, the same in Texas as in every other state. A contractor can quote above the minimum; the rating is on the unit's label and on the AHRI certificate for the matched pair.