HeatCoolHQ heatcoolhq.com (888) 217-3739

Loris, SC

Heat Pump Repair and Replacement in Loris, SC

Heat pump repair in Loris, SC starts by telling a normal defrost cycle or auxiliary-heat run from one that is a fault. Loris has, on average, 39 days a year with a low of 32°F or colder and 2 at 20°F or colder (NOAA 1991–2020 normals, station 18 miles away). Half the homes in Loris were built before 1980 (Census ACS 2019–2023). A split heat pump made since January 1, 2023 must rate at least 14.3 SEER2 and 7.5 HSPF2, a federal floor that does not change from state to state.

(888) 217-3739

South Carolina contractors. No obligation for the call.

The year in Loris—cooling leads, heating gets weeks
The year in Loris. cooling leads, heating gets weeks. Between the two seasons there are weeks when neither system runs, which is when a fault goes unnoticed. nothing runsJFMAMJJASOND
heatingcooling39 days below freezing · July dew point 71°F
A technician checking the coil of an outdoor heat pump in winter
The top grille off, frost across the coil. A heat pump melts that off on a schedule of its own, which looks like a fault and is not.

A heat pump blowing air that feels cool in winter is usually working as designed, and a heat pump that sits on auxiliary heat for hours in mild weather usually is not. Say what the thermostat reads and a heating and cooling contractor can come out to Loris and tell the two apart.

A heat pump in Loris works most of its hours as an air conditioner, and the heating side runs for a few weeks rather than a season. That decides which faults get noticed and when: anything wrong with cooling shows up in July with the whole house paying attention, while anything wrong with heating waits for the first cold week of the year to announce itself.

A gas furnace and a heat pump deliver heat at different temperatures, and the gap is wide. A heat pump supplies air nearer 95°F where a gas furnace supplies it nearer 130°F, and air that arrives near skin temperature, moving, reads as cool — which is why the complaint arrives every year from houses with nothing wrong. What counts is whether the house reaches the setting, and how long it stays short of it: air that feels cool with the house holding at the setting is the machine working, and air that feels cool with the house still short of it at bedtime is not.

A heat pump has to be sized for two different jobs, and in a July this wet the two pull in opposite directions. Size it for the coldest night and it is too large for the cooling season: it drops the temperature, shuts off, and never runs long enough to pull water out of the air, so the thermostat reads 74°F and the house still feels damp. This is the point where a single-stage machine runs out of options, and it is the argument for a compressor that modulates rather than one that is simply larger — long, slow run cycles are what dehumidify. Ask what the sizing was based on: a measurement of the house, with the heating load and the cooling load worked out separately.

Loris, SC in numbers

Days a year with a low of 32°F or colder39NOAA 1991–2020 normals, station 18 miles away
Days a year with a low of 20°F or colder2NOAA 1991–2020 normals
Average July dew point71°FPRISM 1991–2020 normals
Median year homes were built1980Census ACS 2019–2023
Households1,101Census ACS 2019–2023
CountyHorry CountyCensus Bureau
Federal minimum for a new split central AC14.3 SEER2 under 45,000 Btu/h (Southeast)DOE, 2023 standard

What the store-bought fix actually does

A hard-start kit does what it says on the box, and that is the problem with it. It adds starting torque, and a compressor that has begun to struggle will often run another season with one fitted — it is a real part, fitted deliberately on some systems, and not a gimmick. What it cannot do is say why the compressor needed help: a weak run capacitor, worn windings, or a system running at pressures it should not be. A kit fitted and then forgotten hides that question until the compressor answers it.

A technician at an indoor air handler

When to stop and call

  • Ice covers the outdoor coil and the defrost cycles are not clearing it.
  • It cools in summer but will not heat, or it heats but will not cool.
  • Refrigerant was added in an earlier season and the system is behaving the same way again.
The license
Held by the contractor, not by this site, and issued where the work happens — South Carolina licenses at state level, at city level or not at all depending on the trade and the town. Ask for the number and the name it is held under: a trading name and the licensed entity are often not the same.
The figure
Set by the contractor and said before the work starts. This site never quotes and has no part in it. If a technician cannot say what the visit covers before beginning, that is the moment to stop.
The call
Describing what the system is doing commits you to nothing. Nothing is booked until you say so.

What the visit involves

  1. 01

    The diagnosis

    At the thermostat first, then at the furnace or the condenser, in the order the equipment runs. What the system is doing is established before any part is named.

  2. 02

    The repair

    Agreed with the contractor before it starts. Where a part has to be ordered, a technician says so rather than leaving the system apart.

  3. 03

    What happens after

    A system that failed once in a season often fails again in it. Whether that is the same fault or a second one is worth asking while the technician is still there.

What to have ready when you call

  1. 01That it is a heat pump, and what the backup is — electric, or a gas furnace on the same ducts, and not knowing is a fair answer.
  2. 02Both thermostat numbers, and whether the display is showing auxiliary or emergency heat.
  3. 03What the unit outside is doing: iced over, silent, running without stopping, or reversing every few minutes.

Emergency heat is what that setting is for if the house has gone cold, but say on the phone that you switched to it, because it locks out the compressor, and the fault a technician needs to watch stops happening while it is on.

Heat Pumps in Loris: questions

How many freezing days does Loris have?

Loris averages 39 days a year with a low of 32°F or colder and 2 at 20°F or colder, by the 1991–2020 climate normals for a NOAA station 18 miles away. Cooling sizes the equipment here, and the few cold mornings are when the backup heat comes on.

How humid are summers in Loris?

The July dew point in Loris averages 71°F, by the PRISM 1991–2020 climate normals. In air that wet an oversized air conditioner cools the house fast, shuts off before it has dried the air, and leaves rooms cool and clammy, which is why sizing starts with a load calculation for the house.

Can a contractor in Loris still install an R-410A system?

Federally, yes, for equipment made or imported before January 1, 2025: the EPA dropped the January 1, 2026 installation deadline for that stock in a rule effective July 27, 2026. Equipment made since January 1, 2025 is charged with R-454B or R-32 instead, and an outdoor unit built for those is not a listed match for an indoor coil built for R-410A.

Map loads when you reach it

Other services in Loris

Heat Pumps nearby

Call (888) 217-3739