Heat Pump Repair and Replacement in Kemp, TX

A heat pump in Kemp, TX works in both seasons, so its repair or replacement starts with how it behaves in each. Kemp has, on average, 46 days a year with a low of 32°F or colder and 4 at 20°F or colder (NOAA 1991–2020 normals, station 9 miles away). Half the homes in Kemp were built before 1977 (Census ACS 2019–2023). The federal minimum for a split heat pump made since January 1, 2023 is 14.3 SEER2 in cooling and 7.5 HSPF2 in heating, nationwide.

(888) 217-3739

Texas contractors. No obligation for the call.

The year in Kemp—cooling leads, heating gets weeks
The year in Kemp. cooling leads, heating gets weeks. Between the two seasons there are weeks when neither system runs, which is when a fault goes unnoticed. nothing runsJFMAMJJASOND
heatingcooling46 days below freezing · July dew point 70°F
A technician checking the coil of an outdoor heat pump in winter
The top grille off, frost across the coil. A heat pump melts that off on a schedule of its own, which looks like a fault and is not.

Air that feels cool at the vents in winter is usually the heat pump working as designed, and a heat pump that sits on auxiliary heat for hours in mild weather usually is not. Say what the thermostat reads and a heating and cooling contractor can come out to Kemp and tell the two apart.

A heat pump in Kemp works most of its hours as an air conditioner, and the heating side runs for a few weeks rather than a season. That decides which faults get noticed and when: anything wrong with cooling shows up in July with the whole house paying attention, while anything wrong with heating waits for the first cold week of the year to announce itself.

A gas furnace and a heat pump do not deliver heat at the same temperature, and the difference is large. A heat pump supplies air nearer 95°F where a gas furnace supplies it nearer 130°F, and air that arrives near skin temperature, moving, reads as cool — which is why the complaint arrives every year from houses with nothing wrong. What counts is whether the house reaches the setting, and how long it stays short of it: air that feels cool with the house holding at the setting is the machine working, and air that feels cool with the house still short of it at bedtime is not.

Sizing a heat pump means sizing for two jobs at once, and in a July this wet they pull against each other. Sized for the coldest night, it is oversized for the cooling season: it drops the temperature, shuts off, and never runs long enough to pull water out of the air, so the thermostat reads 74°F and the house still feels damp. That is where a single-stage machine runs out of options, and it is the argument for a compressor that modulates rather than one that is simply larger — long, slow run cycles are what dehumidify. Ask what the size was based on: a measurement of the house, with the heating load and the cooling load worked out separately.

Kemp, TX in numbers

Days a year with a low of 32°F or colder46NOAA 1991–2020 normals, station 9 miles away
Days a year with a low of 20°F or colder4NOAA 1991–2020 normals
Average July dew point70°FPRISM 1991–2020 normals
Median year homes were built1977Census ACS 2019–2023
Households451Census ACS 2019–2023
CountyKaufman CountyCensus Bureau
Federal minimum for a new split central AC14.3 SEER2 under 45,000 Btu/h (Southeast)DOE, 2023 standard

Why heat pumps in Kemp do not fix themselves

A heat pump is unusual in that it can fail without going quiet. A machine low on refrigerant, or one whose defrost control has stopped working, does not stop making heat — it falls behind, and the backup heat fills the gap without being asked. The thermostat still reads what it is set to, so the fault turns up on the electric bill rather than in the house. The same shortfall in cooling is easier to spot, because nothing covers for it — which is why a heat pump often gets diagnosed in summer for something it had been doing all through the heating season.

A technician at an indoor air handler

When to stop and call

  • The thermostat sits on auxiliary or emergency heat for hours while it is mild outside.
  • The breaker feeding the outdoor unit or the air handler will not stay in.
  • Refrigerant was added in an earlier season and the system is behaving the same way again.
The figure
Set by the contractor and said before the work starts. This site never quotes and has no part in it. If a technician cannot say what the visit covers before beginning, that is the moment to stop.
The call
Describing what the system is doing commits you to nothing. Nothing is booked until you say so.
Coverage
By town, not by region. Kemp and the towns around it, and it shifts with who is taking calls at the hour you ring.

What a visit in Kemp involves

  1. 01

    The diagnosis

    At the thermostat first, then at the furnace or the condenser, in the order the equipment runs. What the system is doing is established before any part is named.

  2. 02

    The repair

    Agreed with the contractor before it starts. Where a part has to be ordered, a technician says so rather than leaving the system apart.

  3. 03

    What happens after

    A system that failed once in a season often fails again in it. Whether that is the same fault or a second one is worth asking while the technician is still there.

Before you call: what to have ready

  1. 01That the system is a heat pump, and what carries the heat when it cannot — electric, or a gas furnace on the same ducts, and not knowing is a fair answer.
  2. 02Roughly when it was installed, and what the outdoor data plate says it is charged with — R-410A on most systems in service, R-454B on recent ones.
  3. 03What the outdoor unit is doing: iced over, silent, running without stopping, or reversing every few minutes.

If the house has gone cold, emergency heat is what that setting is for — say on the phone that you switched to it, because it locks out the compressor, and the fault a technician needs to watch stops happening while it is on.

Heat Pumps in Kemp: questions

How cold does Kemp get in winter?

Kemp averages 46 days a year with a low of 32°F or colder and 4 at 20°F or colder, by the 1991–2020 climate normals for a NOAA station 9 miles away. Cooling sizes the equipment here, and the few cold mornings are when the backup heat comes on.

What is the July dew point in Kemp?

The July dew point in Kemp averages 70°F, by the PRISM 1991–2020 climate normals. In air that wet an oversized air conditioner cools the house fast, shuts off before it has dried the air, and leaves rooms cool and clammy, which is why sizing starts with a load calculation for the house.

Is a new R-410A system still allowed in Kemp?

Under federal rules, yes, if the equipment was made or imported before January 1, 2025: an EPA rule that took effect on July 27, 2026 removed the January 1, 2026 installation deadline for that stock. Equipment made since January 1, 2025 is charged with R-454B or R-32 instead, and an outdoor unit built for those is not a listed match for an indoor coil built for R-410A.